Engine OperationsEvolution 1.1

Official evolution · ADO-Pumper Task Book · September 2024

1.1 — Single line on tank water, without changeover

Objective: Supply initial attack line on tank water.

In-cab — Secure the rig & engage the pump

1

RIGHT FOOT ON BRAKE

2

SET PARKING BRAKE

3

SHIFT TRANSMISSION TO NEUTRAL

4

SHIFT FROM ROAD TO PUMP (ENGAGE THE PUMP SHIFT CONTROL LEVER)

5

PUMP ENGAGED LIGHT IS ON

6

SHIFT TRANSMISSION TO DRIVE (D)

7

OK TO PUMP LIGHT IS ON AND

7a

SPEEDOMETER REGISTERS ABOUT 15 MPH

Rig note — Engine 34

Engine 34 pump shift operations

  1. Right foot on brake
  2. Neutral
  3. Park brake
  4. Engage "water pump" switch
  5. Green light indicator on
8

EMERGENCY/WARNING LIGHTS ARE ON

9

CHANGE RADIO TO CORRECT CHANNEL

What you are listening for

"It is imperative that the Engineer listen closely to the radio at all times for traffic concerning charging, shutting down or adjusting hose line pressures on hose lines." The Engineer must also monitor the radio for instructions and information that may require action, and be ready to assist members in distress if ordered by the IC.

Engine Company Operations 2023 V-1, Firefighter Assignments, pp.1-8 and 1-11

10

REMOVE RIGHT FOOT FROM BRAKE

11

APPARATUS DOES NOT MOVE

12

EXIT CAB AFTER LOOKING BOTH DIRECTIONS

Out-of-cab — Get water moving

1

VERIFY PUMP IS ENGAGED

2

OPEN TANK TO PUMP

3

CRACK RE-CIRCULATING/TANK FILL VALVE

OPEN TANK FILL / RECIRCULATION

4

SET TO PSI MODE (IF EQUIPPED)

SET PSI CONTROL MODE BUTTON

Rig note — Engine 34 only

PSI/RPM mode is a PUC feature. It is present on Engine 34 (Pierce PUC) and absent from Orem's other pumps — and it is not the same control as the transfer valve.

5

PRIME PUMP (IF NECESSARY)

6

SET WHEEL CHOCKS

This evolution's printed sheet carries the chock step at this position — no correction needed here.

Where chocking sits in the pump skill

"Step 1: Position the apparatus in a safe positon, and immobilize it by setting the parking brake and chocking the wheels." The pump skill chocks with the parking brake, before the pump is engaged; the printed evolution sheet carries it out of the cab at step 6.

ADO Task #19, Basic Pump Skills — Changeover, Operating Procedure, Step 1

7

CLEAR HOSE BED

Check lines are fully deployed

Why the bed has to be empty

On preconnected lines the Back-Up Firefighter's stretching instruction is one sentence: "Ensure that all hose is cleared from the bed."

Hose left in the bed becomes kinks, and the manual repeats the consequence across the Back-Up Firefighter's assignments: chasing kinks, exterior management of the hose and supporting hose around corners and through doorways are the three ways hose movement is supported, and "failure of the Back-Up Firefighter to complete these tasks will lead to the delay in the initial attack line progressing to the seat of the fire."

Engine Company Operations 2023 V-1, Firefighter Assignments, p.1-24 (stretching); the delay statement repeats at pp.1-17, 1-21 and 1-22

8

BREAK ATTACK LINE (IF NECESSARY)

Who coordinates the break

On a 2½" extended lay: after the length of the stretch has been estimated, the Back-Up Firefighter controls the number of lengths that are pulled off the hose bed, then coordinates the break and connection of the hose to a discharge with the Engineer.

Engine Company Operations 2023 V-1, Firefighter Assignments, p.1-24

9

OPEN CORRECT DISCHARGE

CHARGE LINES

The signal to charge

"When the line is flaked and the Nozzle Firefighter is ready, they will signal the Engineer to charge the hoseline. This signal may be verbal, by radio, or by hand signal."

The Nozzle Firefighter then bleeds the line of trapped air and confirms the pressure and pattern are correct, with the nozzle fully opened and the stream directed away from the opening. The manual's boxed note: "The Nozzle Firefighter should never enter the fire area without water."

Engine Company Operations 2023 V-1, Firefighter Assignments, pp.1-15–1-16

10

SET DISCHARGE TO THE RIGHT PRESSURE

CALCULATE PDP → SET PDP

What the pressure depends on

"In order to establish and maintain proper pumping pressures, all Engineers must know how many hoselines, the size and length of the hoseline, the type of nozzles being used, and their flow." Knowledge of the amount and size of hose carried and stretched at operations is what assists the Engineer in determining the proper pressures required.

Engine Company Operations 2023 V-1, Firefighter Assignments, pp.1-8 and 1-11

11

MARK OR NOTE DISCHARGE GAUGE & LINE LENGTH/LOCATION

12

SET MANUAL DISCHARGE RELIEF VALVE

Manual valve: Engine 31 · Engine 3820 · Ladder 32
The pump skill sets it earlier

The printed evolution sheet places this last, at step 12. The ADO pump skill puts the same action sixth, before the circulator/tank-fill valve is opened: "Step 6: Set the relief valve or pressure governor." The two documents differ on placement; this page follows the printed sheet and flags the difference.

Printed order: ADO-Pumper Task Book, Evolution 1.1, Out-Of-Cab step 12 · ADO Task #19, Basic Pump Skills — Changeover, Operating Procedure, Step 6

You are on tank water — no changeover is coming

The tank is a reserve, and it is finite

"A full tank provides a limited reserve water supply in the event that the external water supply is lost unexpectedly."

ADO Task #19, Basic Pump Skills — Changeover (Transition to an External Water Supply)

Why the attack starts on the tank anyway

Whether the first engine lays its own supply or another engine lays it, the attacking engine will have hydrant water relatively quickly — "this doesn't eliminate the need to use the on-board booster tank to supply the initial fire attack, but rather limits the amount of water that will have to be used while waiting for the hydrant water to arrive."

The first arriving engine company may also elect to pass up a water supply, initiate the fire attack off the booster tank, and assign the supply line to the second due engine. Whatever the first-in Company Officer selects, they MUST announce their water supply intentions over the radio so the second due engine can adjust.

Engine Company Operations 2023 V-1, Water Supply, p.5-1

The assignment this evolution matches

1st due, nothing showing and alarms: "Engineer/ADO should fully prepare his engine by completing all steps required to put the pump in service and supply water to hose" · "No hydrant connection made until otherwise warranted by fire involvement" · "Engineer will stay by the pump and monitor radio traffic for further assignments." That is this sheet: pump in service, line charged, no changeover.

Engine Company Operations 2023 V-1, Firefighter Assignments, p.1-9

When supply arrives, that's the next evolution

This evolution ends without a changeover. Transitioning the pump from tank water to an external supply while lines are flowing is Evolution 1.2 — Changeover & supply various hose loads.

Learn the manual — the operator, the line, and the stretch

The Engineer

What the manual makes the Engineer responsible for

"The primary responsibility of the Engineer is the safe delivery of the personnel, apparatus and equipment to a reported fire or emergency and the delivery of water to the operating firefighting force." The listed responsibilities include maintaining the apparatus in a constant state of readiness, effectively operating any apparatus assigned, and "must know how many hose lines, size, length, nozzles, and the flow rates of their apparatus (per OFD hydraulic standard)."

"The Engineer must be thoroughly familiar with the engine apparatus, all the tools and equipment carried on board and the layout of the hose beds" — and "must control how many and what type streams and hose lines are supplied and should confer with and advise the officer when necessary."

In suppression the Engineer's tasks are listed as water supply, pump operations, and observing the conditions of all the hoselines stretched.

Engine Company Operations 2023 V-1, Firefighter Assignments, pp.1-8–1-9

The line you are charging

Occupancy dictates the line

"Using a 1 ¾" on a one to two room involved residential structure, an extended line (alley lay) on a garden style apartment, or a 2 ½" hoseline on a commercial building would be common examples of the occupancy dictating the line used."

Interior operations inside residential structures are "usually best accomplished with a minimum 150 gpm flow provided by 1 ¾" hoselines" — enough flow for multiple rooms of fire while keeping the speed and flexibility needed inside.

On commercial buildings the manual recommends 2½" because of the potential for large volumes of fire, and recommends a minimum of 100' of working line be stretched and flaked for use interior — the Nozzle Firefighter has to account for that additional 50' when estimating.

Engine Company Operations 2023 V-1, Firefighter Assignments, pp.1-12 and 1-14 · Stretching and Operating the Hoseline, p.4-2

ADULTS — when the answer is 2½"

For the "in between" fire — bigger than a 1¾" can handle, not clearly a 2½" job — the manual gives an acronym for when a 2½" hoseline is recommended:

  • A — Advanced fire conditions on arrival.
  • D — Defensive operations.
  • U — Unable to determine seat or location of fire.
  • L — Large, un-compartmentalized area (supermarket, bowling alley, warehouse).
  • T — "Tons of water". Any time you need to deliver a large volume of water 250 gpm or more.
  • S — Standpipe operations.

A middle option exists: a 1¾" line connected to 2½" hose and a shutoff. If conditions deteriorate the crew can back up, disconnect the 1¾", replace the 2½" nozzle and advance the 2½" already stretched.

Engine Company Operations 2023 V-1, Stretching and Operating the Hoseline, p.4-2

The stretch

Who stretches what

The Nozzle Firefighter is responsible for stretching the first hoseline to the point of entry, and in most situations for the first 100' of hose and the nozzle (lead length). Where the Back-Up Firefighter is performing other duties not associated with stretching — water supply, forced entry — the Nozzle Firefighter is responsible for stretching and flaking the entire hoseline.

In Investigation Mode the Nozzle Firefighter stands fast at the engine, size-ups the building, estimates the possible length of the stretch and determines the size of line that may be needed while the Officer and Back-Up Firefighter investigate.

Engine Company Operations 2023 V-1, Firefighter Assignments, pp.1-12–1-13

Estimating the stretch — the manual's rules of thumb

"Estimating the stretch can make or break the success of the initial attack line." The general guidelines given:

  • The average width of a residential property plot is 50'.
  • Front door to rear door of a typical residence is usually covered with 50'.
  • An additional 50' per story may be necessary to reach a fire on the upper floors of a large residential dwelling.
  • For commercial buildings, add the length and width of the building and use that number as the feet of 2½" needed.
  • Break a long stretch down into 50' sections in your mind.

For large multiple dwellings the estimate must also carry the actual distance from the engine to the entrance door, the distance from that door to the base of the stairway, plus one length per floor and one for the fire floor — some buildings need two or more for the fire floor.

Engine Company Operations 2023 V-1, Stretching and Operating the Hoseline, pp.4-3–4-4

Flaking, charging, feeding

Flaking before you charge

After the attack line is stretched, the Back-Up Firefighter makes sure the hose is properly flaked and kink free up to the lead length while the Nozzle Firefighter waits for water. Although the Nozzle Firefighter owns the lead length, the Back-Up Firefighter "should visualize and ensure that the entire line is kink free."

  • One/Two Residential Dwelling and Garden Style Apartments: the hose is generally stretched, flaked and charged outside the structure before advancing inside. When possible it is good practice that the hose be flaked perpendicular to the point of entry — this lets the Back-Up Firefighter move hose inside more efficiently during the advancement.
  • Multi-family dwelling with public hallways: the line can be flaked in the hallway on the fire floor before charging if conditions allow — apartment door intact, no fire in the hall, light smoke. "A good rule of thumb is if you are masking up, you should be calling for water."

Engine Company Operations 2023 V-1, Firefighter Assignments, p.1-25

Feeding the charged line

Once the line is charged the Back-Up Firefighter's position is the door, feeding the line into the fire area — "slowly feeds line to the advancing nozzle team from their position at the doorway." Standing in the doorway itself blocks access, egress and ventilation.

"The Back-Up Firefighter must not push the hoseline to the nozzle team, but instead feed hose at the speed of the nozzle team so that the hoseline advances" — with the slack managed between the doorway and the nozzle.

Engine Company Operations 2023 V-1, Firefighter Assignments, p.1-26

The same setup, in the pump skill's own order

ADO Task #19 — Operating Procedure, Steps 1–7

ADO Task #19 is written for the changeover, but its first seven steps are this evolution — putting the pump in service on tank water before any external supply exists:

  • Step 1 — Position the apparatus in a safe positon, and immobilize it by setting the parking brake and chocking the wheels.
  • Step 2 — Engage the pump, and select the proper gear in the road transmission. Lock the gear into place.
  • Step 3 — Open the tank-to-pump valve (if necessary).
  • Step 4 — Set the transfer valve to the series (to PSI or RMP) positon depending on application.
  • Step 5 — Increase the throttle setting to obtain the desired pressure, priming (if necessary).
  • Step 6 — Set the relief valve or pressure governor.
  • Step 7 — Open the circulator valve or partially open the tank fill valve.

Two placement differences against the printed evolution sheet, both open items rather than corrections: the pump skill opens the circulator/tank-fill valve after priming (Step 7) where the sheet cracks it at out-of-cab step 3, and it sets the relief valve at Step 6 where the sheet sets it at step 12.

ADO Task #19, Basic Pump Skills — Changeover (Transition to an External Water Supply), Operating Procedure

IF THE LINE LOSES WATER

This evolution runs on tank water — there is no external supply to troubleshoot. Work the pump.

Emergency pump operations — the full sequence

1ST DIGIT METHOD

USE 1ST DIGIT METHOD TO DETERMINE ADDITIONAL LIKE VOLUMES REMAINING.

Source. ADO-Pumper Task Book, Evolution 1.1 "Single line on tank water – without changeover" (September 2024 version) — setup, in-cab and out-of-cab steps verbatim, in printed order, with their printed numbering; the underlined "and" in in-cab step 7 and the bolded relief-valve step are as printed. The Engine 34 pump shift sub-sequence and the manual-discharge-relief-valve rig list are the printed sheet's own rig notes.

Merged steps shown in italics under a printed step — open tank fill / recirculation · set PSI control mode button · check lines are fully deployed · charge lines · calculate PDP → set PDP — are from the engine evolution card, 2026-08-28 transcription.

Manual material. Engine Company Operations 2023 V-1: Firefighter Assignments (pp.1-8, 1-9, 1-11, 1-12, 1-13, 1-14, 1-15, 1-16, 1-17, 1-21, 1-22, 1-24, 1-25, 1-26), Stretching and Operating the Hoseline (pp.4-2, 4-3, 4-4), Water Supply (p.5-1) · ADO Task #19, Basic Pump Skills — Changeover. Rig-specific controls: PSI/RPM mode is a PUC feature present on Engine 34 and absent from Orem's other pumps; the manual discharge relief valve rides on Engine 31, Engine 3820 and Ladder 32 per the printed sheet.

See also: My Engine Evolution — the full muscle-memory sheet these merged steps come from.

Version: prototype · Last reviewed 2026-08-30 · Compiled by Engineer Jason Anderson